ESS III leak testing case

Applications

Leak testing of:

  • gas pipelines conforming to DVGW 469
  • water pipelines conforming to DIN 4279 standard and DIN EN 805 standard
  • waste water pipelines and cable ducts

Device description

The DPK III was developed for easy leak testing on pipelines. The case is prepared to be used in rough environments, such as constuction sites.

The product replaces the usual chart recorders used for the purpose of leak testing. The resolution for the pressure measurement is smaller 0.01% of full range. An automated zoom-function makes use of that high resolution and makes it visible in the print-out.

The temperature compensated pressure recording, which is automatically recorded in a separate channel, is used to determine the result of the leak test.

Separate tests are saved  to the on-system memory and can be transferred using a PC and a software evaluation tool for even more cutomized printouts by adding your personal logo and texts.