Gas density measurement - DS2005

Applications

  • density measurement for liquid gas - air mixing devices
  • propane/air, butane/air
  • relative density and calorific value measurement with two component mixtures

Device description

The DS2005 measures online the relative density of gases in a range of dv: 0.20 - 2.20 within seconds. 
The measurement range goes from hydrogen to butane (for example).

Technical specifications

Measurement range (dv)

(0,0) 0,20 - 2,20

Output

4 - 20 mA, bruden 500 Ohm

Accuracy

+/- 1% absolute

Repeatability

0,001 units

Display

4 x 20 grafic LCD

Display time

4 sec + 7 sec dead time

Warmup time

25 min

Power supply

230/110VAC  50/60Hz 

Input gas pressure

15 mbar

Connector gas and off-gas

6x1mm Swagelock

Enclosure

IP 54 stain less steel

Dimensions

600 x 610 x 210 mm, 21 kg

To top